Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Adhes Dent ; 25(1): 159-166, 2023 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-37551926

RESUMO

PURPOSE: To evaluate the bond strength between alternative or conventional luting agents and indirect restorative materials. MATERIALS AND METHODS: Blocks of a polymer-infiltrated ceramic network (PICN, Vita Enamic) and a feldspathic ceramic (FEL, Vita Mark II) were sliced and divided according to the luting agent: resin cement (PICN-RC, FEL-RC), flowable composite (PICN-FC, FEL-FC), or preheated composite (PICN-PH, FEL-PH). The ceramic surfaces were polished, etched with 5% hydrofluoric acid for 60 s, and then a silane layer was applied. Cylinders of the luting agents were built up on the ceramic surfaces. In half the samples, the microshear bond strength (µSBS) was tested after 24 h (baseline). The other half was tested after 5000 thermocycles (5°C-55°C) (aging). The failure modes were determined using a stereomicroscope, and the ceramic surfaces were analyzed using a scanning electron microscope. Data were statistically analyzed with two-way ANOVA. RESULTS: Thermocycling reduced the bond strength values of all experimental groups. Regarding FEL, the preheated composite obtained the highest results. Resin cement showed results similar to the flowable composite at baseline and after aging. The highest results of PICN were obtained from the preheated composite followed by resin cement and flowable composite. Significant differences among the three luting agents were observed before and after aging. The most frequent failures among the experimental groups were adhesive and cohesive in the ceramic. CONCLUSION: Bond strength results indicate that the preheated composite can be an alternative for adhesive cementation when applied on the tested feldspathic ceramic or PICN.


Assuntos
Colagem Dentária , Cimentos de Resina , Cimentos de Resina/química , Propriedades de Superfície , Condicionamento Ácido do Dente/métodos , Cerâmica/química , Porcelana Dentária/química , Cimentos Dentários , Silanos/química , Teste de Materiais , Ácido Fluorídrico/química
2.
J Adhes Dent ; 25(1): 1-12, 2023 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-36633468

RESUMO

PURPOSE: To evaluate the effect of plasma-enhanced chemical vapor deposition (PECVD) with silicon hydride (SiH4) at different times on HT-zirconia surface characteristics and bonding of composite cement before and after thermocycling. MATERIALS AND METHODS: Blocks of HT zirconia were obtained, polished, sintered and divided into five groups, according to PECVD time (n = 31): Zr-30 (30 s), Zr-60 (60 s), Zr-120 (120 s) and Zr-300 (300 s). The control group (Zr-0) did not receive PECVD. X-ray diffraction (XRD), Fourier-transform infrared spectroscopy (FTIR), energy dispersive spectroscopy (EDS) in conjunction with field-emission scanning electron microscopy (FE-SEM), x-ray photoelectron spectroscopy (XPS), goniometry, and profilometry tests were used for chemical and topographic characterization. Monobond N silane (Ivoclar Vivadent) was applied to the surface, and a cylinder of composite cement (Variolink N) was made (3 x 3 mm). Half of the specimens of each group were stored for 24 h or subjected to thermocycling (6 x 103 cycles). A shear bond strength (SBS) test was performed. Results were subjected to one-way ANOVA and Tukey's tests (α = 0.05). RESULTS: For experimental groups, XPS showed that formation of Si-O bonds contributed to increased surface free energy (SFE). FE-SEM and EDS showed that the longer the deposition time, the greater the amount of silicon on the surface. Zr-60 and Zr-300 presented higher and lower surface roughnesses, respectively. The silicon penetrated the microstructure, causing higher stress concentrations. The bond strength to composite cement was improved after all PECVD deposition times. CONCLUSION: The PECVD technique with SiH4, associated with chemical treatment with primer based on silane methacrylate, is a solely chemical surface treatment capable of maintaining bonding between composite cement and HT zirconia.


Assuntos
Colagem Dentária , Silício , Silanos , Propriedades de Superfície , Cimentos de Resina , Cimentos Dentários , Zircônio/química , Resistência ao Cisalhamento , Teste de Materiais , Cerâmica/química
3.
Dent Mater ; 38(12): 2084-2095, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36446649

RESUMO

OBJECTIVE: To assess potential antagonist wear and survival probability of silica-infiltrated zirconia compared to glass-graded, glazed, and polished zirconia. METHODS: Table top restorations made of 3Y-TZP (3Y), 5Y-PSZ (5Y), and lithium disilicate (LD) were bonded onto epoxy resin preparations. Each zirconia was divided into five groups according to the surface treatment: polishing; glaze; polishing-glaze; glass infiltration; and silica infiltration. The LD restorations received a glaze layer. Specimens were subjected to sliding fatigue wear using a steatite antagonist (1.25 ×106 cycles, 200 N). The presence of cracks, fractures, and/or debonding was checked every one/third of the total number of cycles was completed. Roughness, microstructural, Scanning electron microscopy, wear and residual stress analyses were conducted. Kaplan-Meier, Mantel-Cox (log-rank) and ANOVA tests were performed for statistical analyses. RESULTS: The survival probability was different among the groups. Silica infiltration and polishing-glaze led to lower volume loss than glaze and glass-infiltration. Difference was observed for roughness among the zirconia and surface treatment, while lithium disilicate presented similar roughness compared to both glazed zirconia. Scanning electron microscopy revealed the removal of the surface treatment after sliding fatigue wear in all groups. Compressive stress was detected on 3Y surfaces, while tensile stress was observed on 5Y. SIGNIFICANCE: 3Y and 5Y zirconia behaved similarly regarding antagonist wear, presenting higher antagonist wear than the glass ceramic. Silica-infiltrated and polished-glazed zirconia produced lower antagonist volume loss than glazed and glass-infiltrated zirconia. Silica-infiltrated 3Y and lithium disilicate restorations were the only groups to show survival probabilities lower than 85%.


Assuntos
Vidro , Dióxido de Silício , Microscopia Eletrônica de Varredura , Resinas Epóxi
4.
Dent Mater ; 38(6): 1060-1071, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35527035

RESUMO

OBJECTIVES: This study aimed to evaluate the impact of mechanical fatigue cycling using the step-stress approach along with hydrothermaldegradation (134 ºC with a constant pressure of 2 bars for 20 h), and a novel intercalated hydrothermal/fatigue aging protocol on different aspects of the aging resistance of three generations of dental zirconias. METHODS: "Y"Z T (VITA), INCORIS "T"ZI (Dentsply Sirona) and "K"ATANA UTML (Noritake Kuraray) - 1st, 2nd and 3rd generation, respectively-, zirconia disks (N = 153), were divided into 6 groups (n = 3) for monotonic testing and 9 groups (n = 15) for mechanical fatigue testing, according to 3 proposed treatments for each zirconia: CF (control - only mechanical fatigue cycling); AF (aging in hydrothermal reactor at 134 °C for 20 h + mechanical fatigue cycling); AFA (Alternating protocol: 4 steps of 5 h of hydrothermal aging intercalated with mechanical fatigue cycling). Mechanical fatigue aging was performed according to the step-stress approach through biaxial flexural setup (piston-on-3-balls, initial strength: 100 MPa, step: 50 MPa/10,000, frequency: 20 Hz) until failure. Data were analyzed using Kaplan-Meier and Mantel-Cox test (α = 0.05), in addition to Weibull analysis. Fractured disks were analyzed in stereomicroscope, Scanning Electron Microscopy and X-Ray Diffraction. RESULTS: Continuous hydrothermal and mechanical fatigue cycling decreased the fatigue strength of YAF group (516 ± 38 MPa), while the alternating protocol increased it (730 ± 58 MPa). KATANA UTML showed no differences for both treatments and did not undergo t-m phase transformation. The TAF group showed the highest fatigue strength (810 ± 76 MPa) and cycles for failure (147,000.00 cycles). The fracture origin for all specimens was on the tensile side in pre-existing defects. SIGNIFICANCE: INCORIS TZI zirconia had higher fatigue strength and survival rates after hydrothermal and mechanical fatigue aging. Although less resistant, KATANA UTML did not suffer chemical degradation.


Assuntos
Materiais Dentários , Ítrio , Cerâmica , Teste de Materiais , Estresse Mecânico , Propriedades de Superfície , Zircônio
5.
J Adhes Dent ; 24(1): 147-154, 2022 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-35416442

RESUMO

PURPOSE: To determine the interfacial fracture energy (IFE) and stress distribution of Brazil-nut-shaped specimens made of translucent zirconia and resin cement. MATERIALS AND METHODS: Three types of translucent zirconia were used: 3Y-TZP (high, Vita YZ HT), 4Y-TZP (super, Vita YZ ST), and 5Y-TZP (extra, Vita YZ XT). The adhesive surfaces were air abraded and 10-MDP-based resin cement was used. The cemented Brazil-nut-shaped specimens, with an elliptical defect in the center (as in real Brazil nuts), were thermally aged (5°C-55°C; 40,000 cycles). The IFE test was conducted with a piston to apply compression on the specimen, while the adhesive interface was positioned at four different angles (0, 10, 20, and 30 degrees) to measure the IFE during tensile, shear, and mixed failure modes. All adhesive interfaces were observed to determine failure patterns. The finite element analysis (FEA) was used to calculate tensile and shear stress distributions according to inclinations. Statistical analysis was conducted using the Kruskal-Wallis and Dunn's post-hoc tests (95%), as well as the Mann-Whitney test (95%) was applied to compare each group regarding the aging factor. RESULTS: According to Kruskal-Wallis and Dunn's post-hoc tests, there were no statistically significant differences between non-aged (p > 0.05) and aged materials (p > 0.05). However, there was a significant difference between aged and non-aged materials for all inclinations (p < 0.05) (Mann-Whitney test). According to the FEA, the compressive loading of Brazil-nut-shaped specimens at different angles showed a predominance of tensile stress at 0 degrees and shear stress at 30 degrees. CONCLUSION: The IFE under predominantly shear stresses is higher than when specimens are subjected only to tensile stresses, which allows the interpretation that failures in the oral environmental will probably occur preferentially under tensile stresses, because less energy is needed. All translucent zirconia bonded to resin cement has similar IFE, and thermal aging negatively affects these bonding interfaces.


Assuntos
Colagem Dentária , Cimentos de Resina , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície , Zircônio
6.
Braz Dent J ; 32(2): 53-63, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34614061

RESUMO

The present study was a prospective, controlled, randomized, clinical short-term trial aiming to evaluate the clinical performance of adhesively luted, lithium disilicate and feldspathic glass-ceramics onlays over a period up to 2 years. A total of 11 patients (7 female, 4 male; age range: 18-60 years, mean age: 39 years) were selected for this study. Each patient received a maximum of two restorations per group in a split-mouth-design. LD: Eleven onlays, performed with lithium disilicate-based ceramic (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein), and FP: Eleven onlays, performed with feldspathic ceramic (Vita Mark II, Vita Zanhfabrik, Bad Säckingen). Recalls were performed at 2 weeks (baseline = R1), 1 year (R2) and 2 years (R3) after the cementation by three calibrated blinded independent investigators using mirrors, magnifying eyeglasses, probes and bitewing radiographs. The postoperative sensitivity, secondary caries, marginal integrity, marginal discoloration, color match, surface roughness, tooth integrity, and restoration integrity were evaluated. The Friedman test was used to determine if there was a statistically significant difference in time-to-time comparison of the parameters in the ceramics restorations. A total of 95.4% of the restorations were clinically acceptable at the 2-year recall, without a difference for any evaluation parameter for both ceramic materials. Based on the 2-year data, the CAD-CAM onlays manufactured with feldspathic and lithium-disilicate based ceramics showed similar clinical performance.


Assuntos
Restaurações Intracoronárias , Boca , Adolescente , Adulto , Porcelana Dentária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
7.
Braz. dent. j ; 32(2): 53-63, Mar.-Apr. 2021. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1339327

RESUMO

Abstract The present study was a prospective, controlled, randomized, clinical short-term trial aiming to evaluate the clinical performance of adhesively luted, lithium disilicate and feldspathic glass-ceramics onlays over a period up to 2 years. A total of 11 patients (7 female, 4 male; age range: 18-60 years, mean age: 39 years) were selected for this study. Each patient received a maximum of two restorations per group in a split-mouth-design. LD: Eleven onlays, performed with lithium disilicate-based ceramic (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein), and FP: Eleven onlays, performed with feldspathic ceramic (Vita Mark II, Vita Zanhfabrik, Bad Säckingen). Recalls were performed at 2 weeks (baseline = R1), 1 year (R2) and 2 years (R3) after the cementation by three calibrated blinded independent investigators using mirrors, magnifying eyeglasses, probes and bitewing radiographs. The postoperative sensitivity, secondary caries, marginal integrity, marginal discoloration, color match, surface roughness, tooth integrity, and restoration integrity were evaluated. The Friedman test was used to determine if there was a statistically significant difference in time-to-time comparison of the parameters in the ceramics restorations. A total of 95.4% of the restorations were clinically acceptable at the 2-year recall, without a difference for any evaluation parameter for both ceramic materials. Based on the 2-year data, the CAD-CAM onlays manufactured with feldspathic and lithium-disilicate based ceramics showed similar clinical performance.


Resumo O presente estudo é um estudo clínico prospectivo, controlado, randomizado e de longo curto prazo, com o objetivo de avaliar o desempenho clínico de restauraç ões adesivas cerâmica vítrea reforçada com dissilicato de lítio e cerâmica feldspática por um período de até 2 anos. Um total de 11 pacientes (7 mulheres, 4 homens; faixa etária: 18-60 anos, idade média: 39 anos) foram inseridas para este estudo. Cada paciente recebeu duas restaurações por grupo em um delineamento de boca dividida. LD: Onze onlays, realizados com cerâmica à base de dissilicato de lítio (IPS e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein); e FP: Onze onlays, realizados com cerâmica feldspática (Vita Mark II, Vita Zanhfabrik, Bad Säckingen). Os retornos foram realizados em 2 semanas (linha de base = R1), 1 ano (R2) e 2 anos (R3) após a cimentação, por três investigadores independentes, cegos e calibrados, usando espelhos, óculos de aumento, sondas e radiografias interproximais. Foram avaliadas a sensibilidade pós-operatória, cárie secundária, integridade marginal, descoloração marginal, correspondência de cores, rugosidade da superfície, integridade dentária e integridade da restauração. O teste de Friedman (95%) foi utilizado para determinar se havia uma diferença estatisticamente significante na comparação periódica dos parâmetros nas restaurações cerâmicas. Um total de 95,4% das restaurações estava clinicamente aceitável no retorno de 2 anos, sem diferença para qualquer parâmetro de avaliação para ambos os materiais cerâmicos. Com base nos dados de 2 anos, as restaurações CAD-CAM fabricados com cerâmica feldspática e à base de dissilicato de lítio apresentaram desempenho clínico semelhante.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Pessoa de Meia-Idade , Adulto Jovem , Restaurações Intracoronárias , Boca , Estudos Prospectivos , Porcelana Dentária
8.
J Appl Oral Sci ; 28: e20200438, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32997088

RESUMO

OBJECTIVE: Glaze application on monolithic zirconia (Y-TZP) can be a practical approach to improve the mechanical properties of this material. Our study evaluated the effect of glazing side and mechanical cycling on the biaxial flexure strength (BFS) of a Y-TZP. METHODOLOGY: Eighty sintered Y-TZP discs (Ø:12 mm; thickness: 1.2 mm - ISO 6872) were produced and randomly assigned into eight groups (n=10), according to the factors "glazing side" (control - no glazing; GT - glaze on tensile side; GC - glaze on compression side; GTC - glaze on both sides) and "mechanical aging" (non-aged and aged, A - mechanical cycling: 1.2×106, 84 N, 3 Hz, under water at 37°C). Specimens were subjected to BFS test (1 mm/min; 1,000 Kgf load cell) and fractured surfaces were analyzed by stereomicroscopy and SEM. Hsueh's rigorous solutions were used to estimate the stress at failure of glazed specimens. Two-way ANOVA, Tukey's test (5%), and Weibull analysis were performed. RESULTS: The "glazing side", "mechanical aging" and the interaction of the factors were significant (p<0.05). Groups GC (1157.9±146.9 MPa), GT (1156.1±195.3 MPa), GTC (986.0±187.4 MPa) and GTC-A (1131.9±128.9 MPa) presented higher BFS than control groups (Tukey, 5%). Hsueh's rigorous solutions showed that the maximum tensile stress was presented in the bottom of zirconia layer, at the zirconia/glaze interface. Weibull characteristic strength (σo) of the GC was higher than all groups (p<0.05), except to GT, GTC-A and GTC, which were similar among them. The fractography showed initiation of failures from zirconia the tensile side regardless of the side of glaze application and fatigue. CONCLUSION: Glazing zirconia applied on both tensile and compression sides improves the flexural strength of Y-TZP, regardless the mechanical aging.


Assuntos
Porcelana Dentária , Resistência à Flexão , Zircônio , Cerâmica , Teste de Materiais , Estresse Mecânico , Propriedades de Superfície , Ítrio
9.
J. appl. oral sci ; 28: e20200438, 2020. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1134779

RESUMO

Abstract Glaze application on monolithic zirconia (Y-TZP) can be a practical approach to improve the mechanical properties of this material. Objective Our study evaluated the effect of glazing side and mechanical cycling on the biaxial flexure strength (BFS) of a Y-TZP. Methodology Eighty sintered Y-TZP discs (Ø:12 mm; thickness: 1.2 mm - ISO 6872) were produced and randomly assigned into eight groups (n=10), according to the factors "glazing side" (control - no glazing; GT - glaze on tensile side; GC - glaze on compression side; GTC - glaze on both sides) and "mechanical aging" (non-aged and aged, A - mechanical cycling: 1.2×106, 84 N, 3 Hz, under water at 37°C). Specimens were subjected to BFS test (1 mm/min; 1,000 Kgf load cell) and fractured surfaces were analyzed by stereomicroscopy and SEM. Hsueh's rigorous solutions were used to estimate the stress at failure of glazed specimens. Two-way ANOVA, Tukey's test (5%), and Weibull analysis were performed. Results The "glazing side", "mechanical aging" and the interaction of the factors were significant (p<0.05). Groups GC (1157.9±146.9 MPa), GT (1156.1±195.3 MPa), GTC (986.0±187.4 MPa) and GTC-A (1131.9±128.9 MPa) presented higher BFS than control groups (Tukey, 5%). Hsueh's rigorous solutions showed that the maximum tensile stress was presented in the bottom of zirconia layer, at the zirconia/glaze interface. Weibull characteristic strength (σo) of the GC was higher than all groups (p<0.05), except to GT, GTC-A and GTC, which were similar among them. The fractography showed initiation of failures from zirconia the tensile side regardless of the side of glaze application and fatigue. Conclusion Glazing zirconia applied on both tensile and compression sides improves the flexural strength of Y-TZP, regardless the mechanical aging.


Assuntos
Zircônio , Porcelana Dentária , Resistência à Flexão , Estresse Mecânico , Propriedades de Superfície , Ítrio , Teste de Materiais , Cerâmica
10.
Braz Dent J ; 30(5): 505-510, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31596335

RESUMO

The aim of this study was to investigate the three-dimensional wear, volumetric loss and surface roughness after chewing simulation of two glass ceramics. Lithium disilicate (LD, Emax CAD, Ivoclar) and Zirconia reinforced lithium silicate (ZLS, Vita Suprinity, Vita Zhanfabrick) discs (n=20/g) were scanned to obtain stereolithography (STL) files for each sample. All discs were submitted to chewing simulation with sliding configuration (30 N, 300,000 cycles, 6 mm and 1.7 Hz) with steatite as antagonist. The samples were then scanned again and the volume loss and the deepest defect depth was measured using the superimposed file from the baseline using three-dimensional digital parametric inspection software (GOM Inspect, Braunschweig, Germany). Surface roughness (Ra and Rz) was analyzed with a contact profilometer. Data were analyzed by one-way ANOVA and Tukey test (α=0.5%). ANOVA showed significant differences among the groups. Considering the ceramic volume loss, wear depth defect length and Rz roughness, LD (-22.09±5.57%; 0.80±0.06 µm; 3.08±1.02 µm) showed higher mean values than ZLS (-15.67±4.51%; 0.56±0.09 µm; 1.51±0.90 µm). Ra mean values were similar for both materials (p=0.064). All discs exhibited slight surface scratches along with the sliding direction with pitted wear patterns, while large cracks were observed on wear traces. These same areas can be identified in blue, overlapping the STL files before and after chewing simulation in inspection software. The linear reduction generated by sliding contact shows a graph with a similar wear pattern shape. ZLS was more resistant to wear than LD, with less volume loss and shallower surface defects.


Assuntos
Cerâmica , Mastigação , Porcelana Dentária , Teste de Materiais , Propriedades de Superfície
11.
Braz Dent J ; 30(5): 511-518, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31596336

RESUMO

This study evaluated the influence of zirconia surface finishes on the wear of an enamel analogue. 40 zirconia discs were divided into four groups: control (without finish); glazed; polished; polished and glazed. All samples were subjected to wear against steatite antagonists. The specimens underwent roughness, topographic, scanning electron microscopy (SEM) and wettability analyses. Quantitative wear measurements were performed on both steatites and discs. To measure wear of steatites the weight before and after the test and the diameter after the test were used. Profilometer measurements were performed to determine the wear on discs. Roughness, volumetric wear and mass loss were analyzed using the Kruskal-Wallis and Dunn tests (5%), while contact angle values were analyzed with One-way ANOVA and Tukey tests (5%). The polished group had the lowest roughness means, being statistically different from the other groups (p-value=0.0001). The glazed group presented the lowest steatite volumetric wear (p-value=0.0001), but not statistically different from the polished and glazed group, whereas these groups presented the highest zirconia volumetric wear, with statistically different (p-value=0.0002) compared to the others. SEM showed irregularities on the control groups surface, grooves on the polished group, and a homogeneous surface for the glazed group with a few pores. All groups presented contact angles lower than 90 degrees, characterizing hydrophilic surfaces. It can be concluded that just glazed zirconia caused less wear on the antagonist when compared to no finish and polished zirconia.


Assuntos
Porcelana Dentária , Zircônio , Polimento Dentário , Teste de Materiais , Propriedades de Superfície
12.
Braz. dent. j ; 30(5): 505-510, Sept.-Oct. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1039138

RESUMO

Abstract The aim of this study was to investigate the three-dimensional wear, volumetric loss and surface roughness after chewing simulation of two glass ceramics. Lithium disilicate (LD, Emax CAD, Ivoclar) and Zirconia reinforced lithium silicate (ZLS, Vita Suprinity, Vita Zhanfabrick) discs (n=20/g) were scanned to obtain stereolithography (STL) files for each sample. All discs were submitted to chewing simulation with sliding configuration (30 N, 300,000 cycles, 6 mm and 1.7 Hz) with steatite as antagonist. The samples were then scanned again and the volume loss and the deepest defect depth was measured using the superimposed file from the baseline using three-dimensional digital parametric inspection software (GOM Inspect, Braunschweig, Germany). Surface roughness (Ra and Rz) was analyzed with a contact profilometer. Data were analyzed by one-way ANOVA and Tukey test (α=0.5%). ANOVA showed significant differences among the groups. Considering the ceramic volume loss, wear depth defect length and Rz roughness, LD (-22.09±5.57%; 0.80±0.06 µm; 3.08±1.02 µm) showed higher mean values than ZLS (-15.67±4.51%; 0.56±0.09 µm; 1.51±0.90 µm). Ra mean values were similar for both materials (p=0.064). All discs exhibited slight surface scratches along with the sliding direction with pitted wear patterns, while large cracks were observed on wear traces. These same areas can be identified in blue, overlapping the STL files before and after chewing simulation in inspection software. The linear reduction generated by sliding contact shows a graph with a similar wear pattern shape. ZLS was more resistant to wear than LD, with less volume loss and shallower surface defects.


Resumo O objetivo deste estudo foi investigar o desgaste tridimensional, perda volumétrica e rugosidade após a simulação de mastigação de dois materiais vitro-cerâmicos. Discos de dissilicato de lítio (LD, Emax CAD, Ivoclar) e silicato de lítio reforçado com zircônia (ZLS, Vita Suprinity, Vita Zhanfabrick) (n=20/g) foram confeccionados e digitalizados para obtenção de arquivos de estereolitografia (STL) de cada amostra. Todos os discos foram submetidos à simulação de mastigação com configuração deslizante (30 N, 300.000 ciclos, 6 mm e 1,7 Hz) com esteatita como antagonista. As amostras foram escaneadas novamente e a perda de volume e o defeito mais profundo foram medidos usando o arquivo sobreposto da linha de base através de um software de inspeção paramétrica digital e tridimensional (GOM Inspect, Braunschweig, Alemanha). A rugosidade superficial (Ra e Rz) foi avaliada através de rugosímetro de contato. Os resultados foram analisados por ANOVA 1-fator e teste Tukey (α=0,5%). ANOVA mostrou diferenças significantes entre os grupos. Considerando a perda de volume cerâmico, comprimento do defeito e rugosidade Rz, LD (-22,09±5,57%; 0,80±0,06 µm; 3,08±1.02 µm) apresentou valores médios superiores a ZLS (-15,67±4,51%; 0,56±0,09 µm; 1.51±0.90 µm). Todos os discos exibiram pequenos arranhões na superfície conforme a direção de deslizamento com padrões de desgaste, enquanto grandes ranhuras foram observadas nos traços de desgaste. Essas mesmas áreas podem ser identificadas em azul, sobrepondo os arquivos STL antes e depois da simulação de mastigação no software de inspeção. A redução linear gerada pelo contato deslizante mostra um gráfico com uma forma de padrão de desgaste semelhante. ZLS foi mais resistente ao desgaste do que LD, com menor perda de volume e menores defeitos superficiais.


Assuntos
Cerâmica , Mastigação , Propriedades de Superfície , Teste de Materiais , Porcelana Dentária
13.
Braz. dent. j ; 30(5): 511-518, Sept.-Oct. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1039148

RESUMO

Abstract This study evaluated the influence of zirconia surface finishes on the wear of an enamel analogue. 40 zirconia discs were divided into four groups: control (without finish); glazed; polished; polished and glazed. All samples were subjected to wear against steatite antagonists. The specimens underwent roughness, topographic, scanning electron microscopy (SEM) and wettability analyses. Quantitative wear measurements were performed on both steatites and discs. To measure wear of steatites the weight before and after the test and the diameter after the test were used. Profilometer measurements were performed to determine the wear on discs. Roughness, volumetric wear and mass loss were analyzed using the Kruskal-Wallis and Dunn tests (5%), while contact angle values were analyzed with One-way ANOVA and Tukey tests (5%). The polished group had the lowest roughness means, being statistically different from the other groups (p-value=0.0001). The glazed group presented the lowest steatite volumetric wear (p-value=0.0001), but not statistically different from the polished and glazed group, whereas these groups presented the highest zirconia volumetric wear, with statistically different (p-value=0.0002) compared to the others. SEM showed irregularities on the control groups surface, grooves on the polished group, and a homogeneous surface for the glazed group with a few pores. All groups presented contact angles lower than 90 degrees, characterizing hydrophilic surfaces. It can be concluded that just glazed zirconia caused less wear on the antagonist when compared to no finish and polished zirconia.


Resumo Este estudo avaliou a influência dos acabamentos superficiais da zircônia no desgaste de um análogo de esmalte. 40 discos de zircônia foram divididos em quatro grupos: controle (sem acabamento); glazeado; polido; polido e glazeado. Todas as amostras foram submetidas ao desgaste contra antagonistas de esteatita. Os espécimes foram submetidos à análise de rugosidade, topografia, microscopia eletrônica de varredura (MEV) e análise de molhabilidade. Medidas quantitativas de desgaste foram realizadas nos antagonistas e nos discos de zircônia. Para medir o desgaste das esteatitas, foi mensurado o peso antes e depois do desgaste e o diâmetro após o teste. A análise de perfilometria mensurou o desgaste dos discos. Rugosidade, desgaste volumétrico e perda de massa foram analisados pelos testes de Kruskal-Wallis e Dunn (5%), enquanto os valores de ângulo de contato foram analisados com os testes One-way ANOVA e Tukey (5%). O grupo polido apresentou as menores médias de rugosidade, sendo estatisticamente diferente dos demais grupos (p-valor=0,0001). O grupo glazeado apresentou o menor desgaste volumétrico do antagonista (p-valor=0,0001), mas não foi estatisticamente diferente do grupo polido e glazeado, enquanto que esses grupos apresentaram o maior desgaste volumétrico da zircônia, com diferença estatisticamente diferente (p-valor=0,0002) em comparação com os outros. MEV mostrou irregularidades na superfície do grupo controle, sulcos no grupo polido e uma superfície homogênea para o grupo glazeado, com poucos poros. Todos os grupos apresentaram ângulos de contato menores que 90 graus, caracterizando superfícies hidrofílicas. Dentro das limitações deste estudo in vitro, é possível concluir que zircônia glazeada causou menos desgaste ao antagonista quando comparada a zircônia sem tratamento ou polida. Além disso, não foi encontrada diferença no desgaste do antagonista para os grupos de zirconia polida e controle.


Assuntos
Zircônio , Porcelana Dentária , Propriedades de Superfície , Teste de Materiais , Polimento Dentário
14.
J Mech Behav Biomed Mater ; 100: 103403, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31525551

RESUMO

It is important to predict the wear behavior of a material as well as its potential to wear antagonized restorative materials. Thus, this study investigated the performance of zirconia-reinforced lithium silicate (ZLS) after wear with different antagonists. Thirty discs of ZLS were made and divided into three groups according to the antagonist (n = 10). Ten cylinders of each antagonist were also made. The parameters for the simulation of wear were: 30N, horizontal movement of 6 mm, and 1.7 Hz, totaling 300,000 cycles, in distilled water. Wear measurements (volume losses (mm3)) on the ZLS and antagonists were performed by digital optical profilometry or an analytical balance. Hardness of all materials was also measured, whereas roughness and Scanning Electron Microscopy (SEM) were only accessed for the ZLS. The wear and hardness values were subjected to one-way ANOVA and the Tukey Test (95%), while the roughness data was analyzed with paired T-test (95%). The hardness means of all materials were statistically different (zirconia > steatite = ZLS > acrylic resin) (p = 0.0001). Zirconia and steatite severely worn ZLS and only acrylic resin worn surfaces could be measured for roughness, which was significantly higher after wear (p = 0.007). SEM showed the ZLS's wear tracks when worn by steatite and zirconia. It was possible to observe differences of ZLS wear patterns depending on the antagonist and quantify the volumes worn with steatite (17.61 ±â€¯2.65) and zirconia (41.98 ±â€¯19.45), which were significantly different (p = 0.001). Acrylic resin promoted a superficial wear on ZLS that could not be quantified. In terms of the antagonists' materials, zirconia presented significantly different less volume loss compared to acrylic resin and steatite (p = 0.000). It can be concluded that zirconia caused more wear on ZLS than steatite and acrylic resin.


Assuntos
Cerâmica/química , Desgaste de Restauração Dentária , Lítio/química , Óxido de Magnésio/química , Resinas Sintéticas/química , Silicatos/química , Dióxido de Silício/química , Zircônio/química , Porcelana Dentária , Análise do Estresse Dentário , Dureza , Técnicas In Vitro , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície
15.
J Adhes Dent ; 21(4): 355-363, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31432050

RESUMO

PURPOSE: To evaluate the effect of different firing stages (without firing, additional crystallization and glaze firings), hydrofluoric acid (HF) concentrations (5% and 10%), and thermocycling on the bond strength between resin cement and a zirconia-lithium silicate (ZLS) ceramic. MATERIALS AND METHODS: ZLS ceramic (Celtra Duo, Dentsply Sirona) blocks were cut into smaller blocks and divided into 12 groups (N = 72), according to the HF concentration used, firing stage, and thermocycling (n = 6). All specimens were silanized (Monobond N, Ivoclar) and cemented with resin cement (Multilink N, Ivoclar) onto blocks of composite resin (Filtek Z250 XT, 3M). The specimens were immersed in distilled water for 24 h. The blocks were cut into sticks and tested immediately or thermocycled for 10,000 cycles in water (5°C-55°C). Microtensile bond strength (µTBS) testing was then performed in a universal testing machine (0.5 mm/min, 50 kgf load cell). The failure modes of the sticks were examined using SEM and classified as adhesive, predominantly adhesive, or cohesive. Fracture surfaces were topographically evaluated using SEM. The 5% and 10% HF groups were analyzed separately and the data submitted to two-way ANOVA and Tukey's test (p < 0.05). Additional samples were used for SEM topographic analysis of representative ceramic surfaces. RESULTS: The most frequent types of failure were predominantly adhesive between cement and ceramic and adhesive (cement completely covered the composite). Statistically significant differences were found only for the thermocycling factor (p < 0.05) for both HF concentrations. However, for the 10% HF groups, a marked decrease in µTBS was observed after firing and thermocycling. SEM showed superficial irregularities on ZLS without etching, partial and total dissolution of the vitreous matrix and exposure of the crystals using 5% and 10% HF, respectively. CONCLUSION: The crystallization and glaze firings of ZLS ceramics conditioned with 5% HF promoted bond strength maintenance after thermocycling. Thermocycling decreased the bond strength in all groups, but mainly for fired ZLS conditioned with 10% HF.


Assuntos
Cimentação , Colagem Dentária , Cerâmica , Cimentos Dentários , Porcelana Dentária , Análise do Estresse Dentário , Lítio , Teste de Materiais , Cimentos de Resina , Silanos , Silicatos , Propriedades de Superfície , Resistência à Tração , Zircônio
16.
J Adhes Dent ; 21(4): 373-381, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31432052

RESUMO

PURPOSE: To evaluate the influence of different ceramic surface conditioning methods on the fatigue failure load of adhesively cemented simplified lithium-disilicate glass-ceramic restorations. MATERIALS AND METHODS: Ceramic (IPS e.max CAD, Ivoclar Vivadent) (Ø = 10 mm; thickness = 1.2 mm) and epoxy resin (Ø = 10 mm; thickness = 2.3 mm) disks were produced. The ceramic bonding surfaces were treated as follows: no etching and MPS-silane primer application only (MN); etching with 10% hydrofluoric acid (HF) for 20 s followed by primer application (HF + MN); HF + universal multimode adhesive application (HF + SU); etching with a one-step etching primer (ME&P); HF + primer + conventional adhesive (HF + MN + PAB). The epoxy resin disks were etched with 10% HF for 20 s followed by a coat of bonding agent (Multilink Primer A+B). Pairs of ceramic/epoxy resin disks were cemented with composite cement (Multilink N, Ivoclar Vivadent). The mean fatigue failure load was determined by the staircase method (100,000 cycles at 20 Hz frequency; initial load = 1435 N; step size = 72 N). RESULTS: ME&P had the highest fatigue failure load, followed by HF etched groups, while the non-etched condition (MN group) had the lowest. All samples presented radial cracks originating from defects at the conditioned ceramic surface (interface). CONCLUSION: The simultaneous physicochemical conditioning with one-step self-etching ceramic primer promoted the best fatigue behavior results of the glass-ceramic restorations. It might indicate that this one-step conditioning reduces the number of flaws at the ceramic surface due to the slighter surface alterations than those produced by hydrofluoric acid etching, improving the fatigue behavior.


Assuntos
Condicionamento Ácido do Dente , Cerâmica , Porcelana Dentária , Teste de Materiais , Propriedades de Superfície
17.
Braz Dent J ; 30(2): 157-163, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30970059

RESUMO

The aim of this study was to evaluate the failure probability of two types of abutment screws after compressive load and to analyze the stress distribution with finite element method. Sixty (60) single-tooth implant restorations were assembled on titanium implants (e-fix, A.S. Technology - Titanium Fix). The groups were divided into Conventional screw (Screw neck 1.5 ø mm) and Experimental screw (Screw neck constricted with 1.2 ø mm). Specimens were subjected to single load to failure with compressive test according ISO 14801. The fractured specimens were subjected to stereomicroscopy for measurement of remaining screws inside the implant and characterization of fracture origin. Representative specimens were analyzed by scanning electronic microscopy. For finite element method (FEM), an identical 3D model of the two in vitro test groups were used with similar conditions (30º, 100 N load). The stress in the abutment screw was analyzed by von-Mises criteria. The results of strength means were 4132.5 ± 76 MPa and 4528.2 ± 127.2 for conventional and experimental groups, respectively. During microscopy, the mean (mm) of the remaining screw piece inside the implants were 0.97 ± 0.23 and 1.32 ± 0.12 for conventional and experimental groups, respectively. In FEM, the conventional group showed stress concentered in an unfavorable region (peak of 39.23 MPa), while the experimental group showed more stress areas but less concentration than the conventional group (36.6 MPa). In using the tested experimental geometry, the abutment screw can have its strength improved, and the origin of failure can be more favorable to clinical resolution.


Assuntos
Dente Suporte , Projeto do Implante Dentário-Pivô , Falha de Restauração Dentária , Análise do Estresse Dentário , Teste de Materiais , Probabilidade , Estresse Mecânico , Titânio
18.
J Mech Behav Biomed Mater ; 94: 207-212, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30909025

RESUMO

PURPOSE: This study evaluated the effect of different loading pistons, made of various materials and with different elastic moduli acting as antagonist material, on stress distribution and fatigue behavior of a CAD/CAM silica-based ceramic. MATERIALS AND METHODS: Discs of CAD/CAM made silica-based ceramic (N = 60) (VITA MARK II) were divided into six groups (n = 10 per group), according to the test method (M: Monotonic; F: Fatigue) and the antagonist piston material (T: Tungsten; S: Steel; G: Epoxy resin). FT, FS and FG combinations were submitted to mechanical cycling (2 × 106 cycles, 4 Hz, 45 N). The bending stress after fatigue were also valuated using Weibull analysis and the parameters η (eta), ß (beta) and the mean time to failure (MTTF) were calculated. Fractographic analysis and Finite Element Analysis (FEA) were performed. Data were analyzed using ANOVA and Tukey's tests (alpha=0.05). RESULTS: MG presented significantly less bending strength (MPa) (75.6) compared to MT (87.8) and MS (84.4) (p < 0.05). Six specimens from FT (MMTF: 8.3 × 106; ß:0.60; η:5.6 × 106), four from FS (MMTF: 1.9 × 106; ß:1.2; η:2.0 × 106) and one from FG (MMTF: 1.3 × 106; ß:0.48; η:0.64 × 106) survived the fatigue test. The stress peak on the tensile surface of S was similar to that of T and both were less than that of G. The failure origins were on the tensile surface. CONCLUSION: The epoxy resin pistons were able to decrease the bending stress, and life expectancy (faster failure) of a silica-based ceramic compared to tungsten and steel.


Assuntos
Cerâmica/química , Desenho Assistido por Computador , Teste de Materiais , Dióxido de Silício/química , Análise de Elementos Finitos , Propriedades de Superfície , Suporte de Carga
19.
Gen Dent ; 67(1): 71-77, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30644836

RESUMO

This in vitro study evaluated the effect of surface treatments on the microshear bond strength between zirconia and 2 different resin cements. Thirty sintered zirconia blocks (15.5 × 19.0 × 39.0 mm) were allocated into 10 groups according to 2 factors: surface treatment (control [10% isopropyl alcohol], silica coating, primer, hot etching solution, or glaze) and resin cement (conventional dual-curing [Multilink Automix] or self-adhesive [RelyX U100]). Three cement cylinders (0.7-mm diameter × 1.5-mm height) were made on the surface of each zirconia block. The specimens were stored in water for 6 months at 37°C and then submitted to microshear bond strength tests (n = 9 per surface treatment group). The bond strength data were analyzed statistically with Kruskal-Wallis and Dunn tests (P < 0.05). The contact angle was measured with a goniometer on separate surface-treated disc specimens (n = 2 per group). The greatest mean (SD) bond strength values, regardless of cement type, were reported for the groups with the glaze surface treatment: conventional cement, 13.1 (0.26) MPa; and self-adhesive cement, 20.1 (0.23) MPa. The next greatest mean (SD) values were found in the silica coating groups: conventional cement, 7.94 (0.09) MPa; and self-adhesive cement, 9.8 (0.10) MPa. The self-adhesive cement groups presented the greatest bond strength values, except when the primer surface treatment was applied. The zirconia treated with the hot etching solution presented the greatest mean contact angle, 78.23 (SD 1.34) degrees, and bond strengths that were among the lowest achieved, suggesting that low wettability may have influenced bond strengths.


Assuntos
Cerâmica/química , Teste de Materiais , Cimentos de Resina/química , Zircônio/química , Colagem Dentária/instrumentação , Análise do Estresse Dentário , Humanos , Resistência ao Cisalhamento , Propriedades de Superfície
20.
Braz Oral Res ; 32: e106, 2018 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-30379210

RESUMO

The aim of this study was to determine if multiple processing (heat-pressing) of a dental ceramic influences flexural strength, hardness, and microstructure. Ninety bar-shaped specimens (15 mm × 4 mm × 2 mm) of a pressed ceramic (Vita PM9) were fabricated and randomly divided into 6 groups (n = 15) according to the factors "number of pressings" (C1, C2, and C3, fired 1, 2, and 3 times, respectively) and "mechanical cycling" (M). Half of the specimens were mechanically cycled (106 cycles, 45 N, 3.4 Hz, in water) and all specimens were tested for 3-point bending (0.5 mm/min, load 1000 kgf) and Vickers hardness (19.6 N for 20 s). X-ray diffraction was used to characterize the phases and scanning electron microscopy to characterize the microstructure. The flexural strength data was statistically analyzed with Weibull analysis, ANOVA, and Tukey test. Hardness data was evaluated by 2-way ANOVA and Fisher test. All tests were performed with a significance level of 0.05. Two-way ANOVA revealed that neither "number of pressings" (p=0.085) or "mechanical cycling" (0.055) significantly affected flexural strength. But Weibull analysis showed significant difference for Weibull moduli and characteristic strength between groups. For hardness, a statistical difference was seen for the interaction "Number of pressings * Mechanical cycling", (p = 0.016). Hardness decreased in the following order: C1 (775±17.2), CM3 (751±101), CM2 (735±45), C3 (701±82), CM1 (671±82), and C2 (663±92). Fewer defects were observed with an increased number of firings. Therefore, the possibility of recycling PM9 ceramic does not interfere in the evaluated mechanical properties and improves microstructure.


Assuntos
Silicatos de Alumínio/química , Cerâmica/química , Temperatura Alta , Análise de Variância , Testes de Dureza , Teste de Materiais , Microscopia Eletrônica de Varredura , Maleabilidade , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Propriedades de Superfície , Fatores de Tempo , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...